10 Bonus Prints
0575-
87696888
SERVICE@CNJINLING.COM


Homepage > Products > JL JNT Series

JNT Series Rectangular Cross Flow Cooling Tower
JNT Series Rectangular Cross Flow Cooling Tower

Easy accessible driving system.
JNT motors are located on the outside of the unit.
Compared to the motor inside the fan section, it is easier to remove and repair. Outside-installed motor has no trouble of the hot mist. Quiet operation of the motor is achieved through careful design and controlled manufacturing methods of components. Test results prove that our sound levels are the lowest available in the industry and air-conditioning field.

*. We have different kinds of motors to meet customers needs.

CTI STD-201 Certification.
Certification of independent cooling tower institute guarantee JNT Thermal performance.

Patented ( SX-COMB ) fill design.
Energy cost, the thermal design point, and water quality are example of factor which influence the choice of fill.
Base on these customer’s concern, the patented (SX-COMB ) fill design used in the JNT series have been specially designed to induce highly turbulent mixing of the air and water for superior heat transfer and to have strong resistance against to decay or biological attack.
This fill is thermally formed from rigid polyvinyl chloride (PVC), and a higher temperature fill is available for water temperatures exceeding 55’C.

Patented (SX-COMB ) waved fill design significantly increases cooling tower efficiency as its expansive surface area accelerates cooling. This increased efficiency translates to reduced pump head and horsepower requirements. The special configuration of the filler incorporate the function of drift eliminator, louver and heat exchanging surface, make JNT be more compact. The honeycomb shaped louver feature contributes minimum resistance to airflow.

High efficient air-foil axial fan.
Airfoil-shaped blades are totally fabricated from extrusion Aluminum Alloy. Fan hubs are fabricated with hop-dip galvanized circular plate. The aerodynamic shape together with the lower tip speed ensure a lower noise level. The fan are adjustable for in pitch for permitting maximum utilization of rated horsepower and optimum performance. High efficiency with lower tip speed and light weight design ensures low power consumption and low noise and guarantee 100% performance (after Dynamic Balancing Machine, it guarantee the low vibration operation)
* Incase of most noise sensitive area, super-low noise fan application is available, which made by FRP material.

Water distribution system
JNT water distribution system consist of gravity distribution with large orifice nozzle, which greatly reduce clogging and assure constant performance capacity between maintenance interval. When nozzle cleaning is required, each nozzle can be easily removed in place and cleaned.

They are engineered to produce maximum uniformity of water dispersion with the minimum vertical distance by deflecting water flow vertically and laterally, offering more available tower height for fill slat installation

* Distribution basin covers are serviced as the standard, it prevent the water to be exposed to airborne debris which reduces dirt accumulation in the distribution basin.

Single piece Casing & Basin
FRP basin and casing with single piece guarantee leak free operation and corrosion protection. The basin is leak tested at the factory and is provided two years leakproof guarantee. Basin and casing contain stabilization material resisting ultraviolet radiation, therefore they have smooth and clean surface, it is able to bear aging, with a high polish going through a long time.

Mechanical part
*. Pulley is tested dynamic balancing method guarantee the quiet operation without vibration.
*. JNT cooling tower’s grease Lubricator can provide the grease automatically and continuously for the fan shaft bearings. Fitting is located outside Fanstack, It saves a lot of manual work and makes the maintenance more efficient.
*. Totally enclosed bearing with heavy duty self-aligning ball type is designed for a minimum 75,000 hours life span. Cast iron housing and flexible cap protect the bearing from extreme environmental attack such like rain, vibration and various kind of impact.

Factory assembled
JNT cooling tower delivered as finished product. Using hooking and fork-lifting, its installation will be done in shortest leading time. JNT series which tested by factory quality controlled process, provide equal performance and durability comparing other field erected cooling tower. This also provides consistent, high quality construction, guarantees each unite performs as tested in the lab.
Assembling on factory site can also evade the traditional mistakes committed when assembling under the poor site circumstance.

Reliable Mainframe
JNT heavy duty steel structural framework are designed to meet the customer’s requirement for bearing the extreme wind and impact circumstance. Comparing existing cooling tower, JNT decrease the parts in quantity more than 30%. With JNT, less is more, fewer parts means reduced assembly labor requirement and maintenance, that is lower total cost.
*. For application where extremely corrosive condition, SUS 304 steel framework are available.

Velocity recovery stack
For incremental thermal performance, JNT series adopt velocity recovery fan stack. This application can be used to gain extra capacity in tight layout with same horse power.
Fan guard made according to ANSI safety standard, perfectly provide the safe maintenance condition to the engineer against the any danger caused by fan operating.

Stainless Steel Strainer
Stainless strainer protect your air conditioning system such like pump, pipe against physical attacking by debris. It is installed inside of correction pit as the part, it is very easy to attach and dis-attach. It also prevent the voltex may give the damage to water pump, guarantee the long life span of your air-condition system.

Easy fill cleaning and replacement.
Integrated with eliminator and louver ,JNT fills are hung by galvanized steel support bar which passes through the fill. JNT compact small package design advantage is easier to be taken out the fill for cleaning. JNT series cooling towers service easy fill replacement with just simple work.

Mechanical parts protection
In due to cooling tower are installed outside, therefore mechanical parts are always exposed extreme circumstance such like rain, winds, sunbeams etc. JNT Mechanical parts are perfectly protected from any danger with pulley cover, motor cover, belt cover and any others protective equipment.

Largest working platform
JNT Series provide largest working platform for maintenance work. The platform is located between two access door of the cooling tower for easier inspection. Access door is made of F.R.P. and it has sufficient size to enter into tower without inconvenience. This advantage allows the maintenance without shuting down the cooling tower.


JNT Series Rectangular Cross Flow Cooling Tower PDF Documents

Why choose JNT PDF文件 358KB >   JNT Series Selection Chart PDF文件 275KB >
 


Get Adobe Acrobat Reader To view the PDF files, you will need Acrobat Reader Version 5.0 or higher.

Copyright © 2005 -2008  ZheJiang Jinling Refrigeration Engineering Co.Ltd . All Rights Reserved
浙ICP备05004121号